10.4
General-purpose parameters
In the Unidrive there are general-purpose parameters for use with
programs.
Parameters marked as
altered using the keypad of the Drive.
be altered using the keypad.
Unidrive parameter
numbers
#18.01
#18.02 ~ #18.10
#18.11 ~ #18.30
#18.31 ~ #18.50
#19.01
#19.02 ~ #19.10
#19.11 ~ #19.30
#19.31 ~ #19.50
#20.01 ~ #20.50
Note
The Menu-20 parameters are stored in the non-volatile
memory in the UD70, not in the Drive. To store these
parameters, set #17.19 at 1. Parameters will be stored at
power-down also when #17.20 is set at 1.
10-12
Parameters
can be altered by the
RO
UD70,
indicates that the parameter can
RW
Description
Read-only parameter. Stored by
the Drive at power-down.
Read-only parameters.
Read-write parameters.
Bit parameters.
Read-only parameter. Stored by
the Drive at power-down.
Read-only parameters.
Read-write parameters.
Bit parameters.
Parameters stored in the UD70.
UD70
but they cannot be
Type
Range
±32000
RO
±32000
RO
±32000
RW
RW
0 or 1
±32000
RO
±32000
RO
±32000
RW
RW
0 or 1
±32000
RW
UD70
Issue code: 70nu2