Step 10
After 5 minutes, open the prime plug. Press the PUMP
key. Pull the draw handle down and draw off the
remaining sanitizer.
Figure 49
Step 11
Once the sanitizer stops flowing from the door spout,
close the draw valve. Press the PUMP and WASH
keys to stop operation. Disconnect the pressure line
from the pressure switch. Drain the sanitizer and
reconnect.
IMPORTANT: The unit must NOT be placed in AUTO
until all sanitizing solution has been removed from the
freezing cylinder and proper priming procedures have
been completed. Failure to follow this instruction may
result in damage to the freezing cylinder.
Note: On the Models 8756 and 8757, momentarily
pull down the center draw handle to sanitize the center
door spout.
Step 12
Repeat Steps 1 through 11 for the second freezing
cylinder on the Models 8756 and 8757.
Step 13
Prepare a sink with an approved sanitizing solution
(examples: Stera SheenR or Kay−5R). USE WARM
WATER AND FOLLOW THE MANUFACTURER'S
SPECIFICATIONS.
Step 14
Take the following parts to the sink and sanitize: mix
tank(s), mix tank cover(s), mix probe(s), mix storage
cover(s) and funnel(s).
Models 8752, 8756, 8757

Priming

Step 1
Place the mix tank and the cover in the mix cabinet.
Step 2
Insert the prongs of the mix probe inside the mix tank
and connect the mix probe in the socket receptacle.
Step 3
Place the free end of the suction line down in the mix
tank.
31
Figure 50
Figure 51
150625
Operating Procedures