Step 7
Press the PUMP key. A light will come on, indicating
the air/mix pump is operating. This action will cause
the sanitizing solution to be pumped through the
air/mix pump and out through the pressure line. After
approximately 15 seconds, press the PUMP key. The
light will go out and the pump will stop operation.
Figure 45
Step 8
Drain and connect the free end of the pressure line to
the pressure switch.
Figure 46
Operating Procedures
Step 9
Place an empty pail beneath the door spout and raise
the prime plug.
Press the WASH and PUMP keys. The lights will come
on, indicating the pump and beater motor are
operating. When a steady stream of sanitizing
solution is flowing from the prime plug hole in the
bottom of the freezer door, press the PUMP key,
stopping pump operation. Push down the prime plug
and allow beater agitation for 5 minutes.
30
Figure 47
Figure 48
Models 8752, 8756, 8757