PROBLEM
4. Product is too soft.
5. Mix in the mix cabinet is
too warm.
6. Mix in the mix cabinet is
too cold.
7. Excessive mix leakage
from the bottom of the
door spout.
Models 8752, 8756, 8757
PROBABLE CAUSE
a. Viscosity control is set too
warm.
b. Worn scraper blades.
c. Dirty condensers or air
filters on air cooled units.
d. Inadequate water supply
on water cooled units.
e. Draw rate is set too fast.
f. Inadequate air space
around air cooled units.
a. Warm mix was placed in
the tank.
b. The mix cabinet door was
left open.
c. The mix cabinet
refrigeration system needs
adjustment.
d. The mix cabinet door
gasket is not sealing.
e. Dirty mix cabinet
condenser or air filter.
a. The mix cabinet
refrigeration system needs
adjustment.
b. Worn, missing or incorrect
o−ring is on the draw
valve.
c. Improper lubrication on
the draw valve o−rings.
41
REMEDY
a. Contact a service
technician.
b. Replace scraper blades
regularly.
c. Clean monthly.
d. Check the water supply.
Check water lines for
leaks or kinks.
e. Adjust the draw rate to 5
to 7−1/2 ounces of
product every 10 seconds.
Check that the restrictive
bar on the draw handle is
assembled on the bottom.
f. Allow adequate room for
air flow across the
condensers. Minimum of
3" (7.6 cm) clearance on
all sides. Do not obstruct
air discharge on top. 12"
(30.5 cm) clearance on
top of freezer.
a. Mix added to the mix tank
should be below 40_F
(4.4_C).
b. The door must be kept
closed.
c. Contact a service
technician.
d. Repair or replace gasket.
e. Clean monthly.
a. Contact a service
technician.
b. Check the o−rings.
(Replace every 3 months.)
c. Lubricate properly.
Troubleshooting Guide
PAGE
REF.
− − −
44
38
1/ 38
18
1
37
32
− − −
− − −
38
− − −
44
22

Hide quick links: