The Air/Mix Pump; Winter Storage - Taylor 8752 Operator's Manual

Soft serve freezers
Table of Contents

Advertisement

j 7. If your machine is air cooled, check the
condensers for accumulation of dirt and lint.
Dirty condensers will reduce the efficiency and
capacity of the machine. Condensers should be
cleaned monthly with a soft brush.
Note: For machines equipped with an air filter,
it will be necessary to vacuum clean the filters
on a monthly schedule.
Never use screwdrivers or other
metal probes to clean between the fins.
j 8. On water cooled units, check the water lines for
kinks or leaks. Kinks can occur when the
machine is moved back and forth for cleaning or
maintenance
purposes.
cracked water lines should be replaced only by
an authorized Taylor technician.
j 9. Your machine is equipped with an auxiliary
refrigeration system. Check the auxiliary
condenser for accumulation of dirt and lint. Dirty
condensers will reduce the refrigeration
capacity of the mix cabinet. Condensers must
be cleaned monthly with a soft brush.
Note: For machines equipped with an air filter,
it will be necessary to vacuum clean the filters
on a monthly schedule.
Never use screwdrivers or other
metal probes to clean between the fins.
080820
Important: Operator Checklist
Deteriorated
or
38

The Air/Mix Pump

j 1. Dispose of the o−rings, the check bands and
the pressure switch diaphragm if they are worn,
torn or fit too loosely and replace with new ones.
j 2. Follow lubricating procedures carefully. NEVER
lubricate check bands.
j 3. Handle plastic pump parts with care to avoid
nicks and cracks.
j 4. Be sure the pressure line is securely attached
to the pressure switch.
j 5. Clean, sanitize and lubricate the pressure
switch diaphragm daily.
j 6. Be sure the air/mix pump is properly aligned
with the face plate of the motor reducer or
severe and costly damage may occur.

Winter Storage

If the place of business is to be closed during the winter
months, it is important to protect the freezer by
following certain precautions, particularly if the
building is subject to freezing conditions.
Disconnect the freezer from the main power source to
prevent possible electrical damage.
On water cooled freezers, disconnect the water
supply. Relieve pressure on the spring in the water
valve. Use air pressure on the outlet side to blow out
any water remaining in the condenser. This is
extremely important. Failure to follow this procedure
may cause severe and costly damage to the
refrigeration system.
Your local Taylor Distributor can perform this service
for you.
Wrap detachable parts of the freezer such as the
beater, blades, drive shaft, and freezer door. Place
these parts in a protected, dry place. Rubber trim parts
and gaskets can be protected by wrapping them with
moisture−proof paper. All parts should be thoroughly
cleaned of dried mix or lubrication which attract mice
and other vermin.
Models 8752, 8756, 8757