Taylor 8752 Operator's Manual page 47

Soft serve freezers
Table of Contents

Advertisement

PROBLEM
11. The air/mix pump does
not operate.
12. The machine will not
operate in the AUTO
mode.
Models 8752, 8756, 8757
PROBABLE CAUSE
a. The pump motor is not
activated.
b. Defective air/mix pump
pressure switch.
c. The pressure switch
diaphragm was installed
incorrectly or was missing.
a. The machine is
unplugged.
b. The circuit breaker is off
or the fuse is blown.
c. Low on mix. The MIX
OUT light is flashing.
d. The mix probe is not
installed properly or is
damaged.
e. The beater motor is out on
reset.
f. The unit is off on high
head pressure.
g. The power switch is in the
OFF position.
43
REMEDY
a. Place the power switch in
the OFF position. Push
the reset button on the
pump drive motor. Return
the power switch to the
ON position. (Models
8756 and 8757, press the
AUTO key for the opposite
freezing cylinder also.)
b. Contact a service
technician to replace the
pressure switch.
c. The diaphragm must be
correctly installed in the
pressure switch cap or the
housing.
a. Plug the machine into the
wall receptacle.
b. Turn the breaker on or
replace the fuse.
c. Add mix to the mix tank
and press the AUTO key.
d. Check the mix probe
installation.
e. Reset the freezer.
f. Air cooled: clean the
condenser.
Water cooled: check the
water supply.
Contact a service
technician.
g. Place the power switch in
the ON position.
Troubleshooting Guide
PAGE
REF.
− − −
− − −
27
− − −
− − −
16
31
16
38/ 38
29

Hide quick links: