6 Observe the described ESD measures when handling the modules.
7 Remove the CANsync-Master option module for b maXX PLC from the transportation
packaging: Avoid contact with the plug-in module's electronic components.
8 Plug the CANsync-Master option module for b maXX PLC into the slot's guide rails.
The gripping piece must face the same way as the other gripping pieces in this slot rail
slot rail (in the case: the right-hand side).
9 Keep pressing two fingers on the front panel until you feel the card engage in the end
position inside the unit.
10 Turn the spagnolet locks above and below this slot by 90° to the vertical position
(locked position).
11 Remount the cover on the unit.
NOTE
If you only want to replace the CANsync-Master option module for b maXX PLC within the
scope of repairs with a card of the same type, the rest of the procedure is considerably short-
er. In this case, you only need to restore the connections to the module, put the front cover
back on and switch the unit on again.
This completes assembly of the CANsync-Master option module for b maXX PLC. Con-
necting lines and commissioning is shown in the following sections.
Operating Instructions CANsync-Master Option Module for BM4-O-PLC
Assembly and installation
BM4-O-CAN-06
5
25
von 56