Labrie Expert 2000 Maintenance Manual page 61

Hide thumbs Also See for Expert 2000:
Table of Contents

Advertisement

6.
Push the green
button to fully extend the packer,
then push the red emergency
button when the packer is
S
TOP
fully extended.
Emergency
Stop Button
Figure 71. Right-hand side control
station
Figure 72. Extended packer
7.
Apply the Lockout/Tagout
procedure. Refer to "Lockout/
Tagout Procedure" on page 8.
S
C
TART
YCLE
Start
Cycle
Button
Maintenance Manual
DANGER
A
PPLY
THE
PROCEDURE TO PREVENT ANY ENGINE
-
.
START
UP
8.
Locate the limit switches at the
front end of the body, on its
right-hand side, between the cab
and the body (Figure 73. "Packer
cylinder limit switches");
Packer-
Extension
Limit Switch
Figure 73. Packer cylinder limit
switches
9.
Srew or unscrew the
limit-switch-finger adjustment
screw (Figure 74. "Packer
cylinder finger") so the cylinder
lever can trigger the switch when
the packer cylinder reaches this
position;
Expert(t) 2000
51
TM
/
LOCKOUT
TAGOUT
Packer-
Retraction
Limit Switch