Problem
Packing is
insufficient
Problem
The backup alarm
and the warning
buzzer in the cab
are continuously
on and do not
stop.
Possible cause(s)
Low hydraulic pressure
Packer limit switches are
not properly set up.
The hydraulic system
prematurely switches off.
Possible cause(s)
Tailgate limit switch needs
adjustment.
Faulty electrical harness
Expert(t) 2000
Maintenance Manual
Solution(s)
Adjust the hydraulic
pressure. Call the Labrie
Customer Support Center
for details.
Verify and adjust the
packer limit switches.
"Limit Switches
Adjustment" on page 48.
Verify the packer cylinder
which may be bypassing.
Refer to "Hydraulic
Cylinder Inspection
Procedures" on page 88
for details.
Solution(s)
"Tailgate Limit Switch
Adjustment" on page 84.
Troubleshoot the electrical
harness connected to the
tailgate limit switch.
Change the electrical
harness if necessary.