Labrie Expert 2000 Maintenance Manual page 103

Hide thumbs Also See for Expert 2000:
Table of Contents

Advertisement

6.
Disengage the pump;
7.
Stop the engine;
8.
Clean around the filler cap and
remove it.
CAUTION
S
OME
HYDRAULIC
(3
5 PSI). U
PRESSURIZED
TO
THE FILLER CAP SLOWLY
9.
Use a clean container with a
minimum capacity of 60 US
gallons to collect the oil;
10.
To drop the oil, remove the drain
plug under the tank.
11.
Completely drain the tank;
12.
Once the system emptied,
reinstall the drain plug, ;
13.
Remove and clean the strainer
(once a year);
14.
Change the return filter element
(twice a year);
15.
Open the access cover. (Refer to
"Figure 145. Hydraulic tank" on
page 93 for details.)
16.
and clean the inside of the tank
of any metal particles or debris
that may have accumulated at
the bottom;
TANKS
ARE
NSCREW
.
17.
Note:Use a high quality oil, that has
Maintenance Manual
Strainer
Filler/
Breather Cap
Figure 145. Hydraulic tank
Refill the tank until oil reaches
3/4 of the oil gauge (Figure
1.83).
good performance in cold
weather (if applicable), such
as Shell Tellus T32 or
equivalent (refer to
"Lubrication" on page 123)
The whole system will require
between 50 and 60 gallons;