Filter Head
Cover
Figure 147. Hydraulic tank's filter
head cover
To replace the hydraulic filter, apply
the following procedure:
1.
Make sure the parking brake is
applied and the vehicle is tagged
out for maintenance purposes
(refer to "Lockout/Tagout
Procedure" on page 8);
DANGER
A
PPLY
THE
LOCKOUT
PROCEDURE
AT
ALL
MAINTENANCE
OR
CARRIED OUT ON THE VEHICLE
2.
Prepare a pan or a bucket to
recuperate oil that will spill out of
the filter housing (2 gallons of
oil);
3.
Remove the four (4) bolts of the
filter head cover of the hydraulic
4.
Cover
Retaining
Bolts (4)
/
TAGOUT
TIMES
WHEN
INSPECTION
IS
.
5.
Maintenance Manual
tank (Figure #1.91); this in-tank
return filter system has a
selfclosing trap that is closing as
you remove the cartridge
therefore preventing the whole
tank to empty itself.
Change the filter element with a
new one (Figure 148. "Filter
element");
WARNING
C
HANGE
RETURN
FILTER
50
AFTER
THE
FIRST
.
OPERATION
Figure 148. Filter element
Reinstall the filter head cover.