Commissioning

5 Commissioning

5.1 Safety Instructions

See chapter 2 Safety for general safety instructions.
WARNING
5
5
HIGH VOLTAGE
Adjustable frequency drives contain high voltage when
connected to AC line power. Failure to perform instal-
lation, start-up, and maintenance by qualified personnel
could result in death or serious injury.
Installation, start-up, and maintenance must be
performed by qualified personnel only.
Before applying power:
1.
Verify that there is no voltage on input terminals
L1 (91), L2 (92), and L3 (93), phase-to-phase and
phase-to-ground.
2.
Verify that there is no voltage on output
terminals 96 (U), 97 (V), and 98 (W), phase-to-
phase and phase-to-ground.
Confirm continuity of the motor by measuring Ω
3.
values on U-V (96-97), V-W (97-98), and W-U
(98-96).
4.
Check for proper grounding of the adjustable
frequency drive as well as the motor.
5.
Inspect the adjustable frequency drive for loose
connections on the terminals.
6.
Check that all cable connectors are firmly
tightened.
7.
Ensure that input power to the unit is OFF and
locked out. Do not rely on the adjustable
frequency drive disconnect switches for input
power isolation.
8.
Confirm that the supply voltage matches the
voltage of the adjustable frequency drive and the
motor.
9.
Close the door properly.

5.2 Applying Power

Apply power to the adjustable frequency drive using the
following steps:
1.
Confirm that the input voltage is balanced within
3%. If not, correct the input voltage imbalance
36
®
VLT
AutomationDrive FC 302
2.
3.
4.

5.3 Local Control Panel Operation

5.3.1 Local Control Panel
The local control panel (LCP) is the combined display and
keypad on the front of the unit.
The LCP has several user functions:
An optional numeric LCP (NLCP) is also available. The NLCP
operates in a manner similar to the LCP. See the product
relevant programming guide for details on use of the NLCP.
NOTICE!
For commissioning via PC, install the MCT 10 Set-up
Software. The software is available for download (basic
version) or for ordering (advanced version, order number
130B1000). For more information and downloads, see
www.danfoss.com/BusinessAreas/DrivesSolutions/Software
+MCT10/MCT10+Downloads.htm.
5.3.2 Start-up Message
NOTICE!
During start-up, the LCP displays the message
INITIALIZING. When this message is no longer displayed,
then the adjustable frequency drive is ready for
operation. Adding or removing options can extend the
duration of start-up.
Danfoss A/S © 06/2015 All rights reserved.
before proceeding. Repeat this procedure after
the voltage correction.
Ensure that any optional equipment wiring
matches the installation application.
Ensure that all operator devices are in the OFF
position. Close all panel doors and fasten covers
securely.
Apply power to the unit. DO NOT start the
adjustable frequency drive now. For units with a
disconnect switch, turn it to the ON position to
apply power to the adjustable frequency drive.
Start, stop, and control speed when in local
control.
Display operational data, status, warnings and
cautions.
Program adjustable frequency drive functions.
Manually reset the adjustable frequency drive
after a fault when auto-reset is inactive.