Danfoss VLT AutomationDrive FC 302 Instruction Manual page 66

0–315 kw d-frame
Hide thumbs Also See for VLT AutomationDrive FC 302:
Table of Contents

Advertisement

Specifications
Type designation
High/normal load*
Typical shaft output at 550 V [kW]
Typical shaft output at 575 V [hp]
Typical shaft output at 690 V [kW]
Enclosure protection rating IP21
Enclosure protection rating IP54
Enclosure protection rating IP20
Output current
Continuous (at 550 V) [A]
Intermittent (60 s overload) (at 550 V) [A]
Continuous (at 575/690 V) [A]
Intermittent (60 s overload) (at 575/690 V) [kVA]
Continuous kVA (at 550 V) [kVA]
Continuous kVA (at 575 V) [kVA]
Continuous kVA (at 690 V) [kVA]
Maximum input current
Continuous (at 550 V) [A]
8
8
Continuous (at 575 V) [A]
Continuous (at 690 V)
Additional specifications
Maximum cable size: Line power, motor, brake and load
share mm (AWG)
Maximum external electrical fuses [A]
Estimated power loss at 575 V [W]
Estimated power loss at 690 V [W]
Weight, enclosure protection rating IP21, IP54 kg (lbs.)
Weight, enclosure protection rating IP20 kg (lbs.)
Efficiency
2)
Output frequency
Heatsink overtemperature trip
Control card ambient trip
*High overload=150% current for 60 s, Normal overload=110% current for 60 s.
Table 8.3 Line Power Supply 3x525–690 V AC
1) Applies for dimensioning of adjustable frequency drive cooling. If the switching frequency is higher than the default setting, power loss may
increase. LCP and typical control card power consumption is included. For power loss data according to EN 50598-2, refer to www.danfoss.com/
vltenergyefficiency.
2) Efficiency measured at nominal current. For energy efficiency class, see chapter 8.4 Ambient Conditions. For part load losses, refer to
www.danfoss.com/vltenergyefficiency.
The typical power loss is at nominal load conditions and expected to be within ±15% (tolerance relates to variety
in voltage and cable conditions).
The losses are based on the default switching frequency. The losses increase significantly at higher switching
frequencies.
The options cabinet adds weight to the adjustable frequency drive. The maximum weights of the D5h–D8h frames
are shown in Table 8.4.
64
®
VLT
AutomationDrive FC 302
HO
160
250
200
253
380
242
363
241
241
289
245
234
240
3012
1)
3121
1)
Danfoss A/S © 06/2015 All rights reserved.
N200
N250
NO
HO
200
200
300
300
250
250
D2h
D2h
D2h
D2h
D4h
D4h
303
303
333
455
290
290
319
435
289
289
289
289
347
347
299
299
286
286
296
296
2x185 (2x350)
550
3723
3642
3848
3768
125 (275)
125 (275)
0.98
0–590 Hz
110 °C (230 °F)
75 °C (167 °F)
N315
NO
HO
NO
250
250
315
350
350
400
315
315
400
D2h
D2h
D4h
360
360
418
396
540
460
344
344
400
378
516
440
343
343
398
343
343
398
411
411
478
355
355
408
339
339
390
352
352
400
4465
4146
5028
4610
4254
5150
MG34U422