Connecting And Configuring Optional Hardware; Hardware Overview - HP HPE G2 Series User Manual

Metered, switched, and metered & switched power distribution unit
Table of Contents

Advertisement

Connecting and configuring optional hardware

Hardware overview

HPE G2 Series Metered, Switched, and Metered & Switched Power Distribution Units monitor environmental
conditions of a rack with the addition of HPE optional environmental sensors. Conditions such as
temperature, humidity, leak detection, and intrusion can be monitored with the sensors. These conditions are
all vital aspects of maintaining an efficiently performing data center. Users and administrators can monitor the
status and view reports and alarms of specific conditions in and around a PDU or server rack.
The following environmental sensors are available:
Temperature sensor
Temperature and humidity sensor
3-temperature + 1-humidity sensor
Open/Close door sensor
Leak detection sensor
Sensor port hub
Leak detection sensor extension
Sensor
Temperature sensor
Temperature and
humidity sensor
3-temperature + 1-
humidity sensor
Open/Close door sensor
Rope fluid leak sensor
Sensor port hub
Leak detection sensor
extension
The optional environmental sensors can be installed before or after completing the PDU installation or startup,
and can be installed without turning off power to the PDU or the devices connected. HPE G2 Series Metered,
110
Connecting and configuring optional hardware
SKU
Description
P9T00A
Monitors the temperature in the rack.
P9T01A
Monitors the temperature and relative humidity
in the rack.
P9T02A
Monitors the temperature in three areas using
three separate probes, and the relative humidity
using one probe.
P9T03A
Sends an alarm or notification when a door on
which the sensor is installed has been opened
more than 10 mm. This kit includes two door
contacts (one for the front and one for the rear
door).
P9T04A
Monitors for early detection of liquid with a
resistivity of less than 2M Ohms (including
distilled water) in the monitored area. The kit
includes a 6m rope, and optional additional rope
can be added (see P9T08A).
P9T07A
Allows for up to three environmental sensors to
be connected to the PDU.
P9T08A
The kit includes one additional 6m length rope
to pair with the leak detection sensor (P9T03A).
A total of four extensions can be added to the
leak detection sensor for a total length of 30m.
Sensor
Measurement
1
2
4
2
1
N/A