Storage And Disposal; Storage; Disposal - Edwards RV3 Instruction Manual

Rotary vane pumps
Hide thumbs Also See for RV3:
Table of Contents

Advertisement

6

Storage and disposal

6.1

Storage

Observe the storage temperature limits stated in
pump seals.
Note:
If a new pump is to be stored in conditions of high humidity, remove the pump from its cardboard packaging
box; dispose of the box (refer to
Use the following procedure to store the pump:
1. Shut-down the pump as described in
2. Disconnect the pump from the electrical supply.
3. Purge the vacuum system and the pump with dry nitrogen and disconnect the pump from the vacuum system.
4. Replace the oil as described in
5. Place and secure protective covers over the inlet and outlet-ports.
6. Store the pump in cool, dry conditions until required for use. When required, prepare and install the pump as
described in
Section
3. If the pump has been stored for more than a year, before installing the pump it must be
cleaned and overhauled as described in the instructions supplied with the clean and overhaul kit.
6.2

Disposal

Dispose of the pump and any components removed from it safely in accordance with all local and national safety and
environmental requirements.
Take particular care with components and waste oil which have been contaminated with dangerous process
substances.
Do not incinerate fluoroelastomer seals and O-rings.
© Edwards Limited 2018. All rights reserved.
Edwards and the Edwards logo are trade marks of Edwards Limited.
CAUTION
Section
2.1. Storage below -30°C will permanently damage the
Section
6.2).
Section
4.8.
Section
5.4.
A652–01–880 Issue Y