Configuring With Step 7; Rules For Arranging Fault-Tolerant Station Components - Siemens SIMATIC CPU 410 System Manual

Process control system, process automation/cpu
Table of Contents

Advertisement

Supplementary information

18.4 Configuring with STEP 7

SSL-ID
PROFINET IO
W#16#0D91
Yes
Parameter adr1 changed
No, external interface
W#16#xy92
No
Replacement: SSL-ID
W#16#0x94
W#16#0x94
Yes, internal interface
No, external interface
W#16#0C96
Yes, internal interface
No, external interface
W#16#0591
Yes
Parameter adr1 changed
W#16#0696
Yes, internal interface
No, external interface
Detailed information
For detailed descriptions of the individual system status lists, refer to Manual
Software for S7-300/400 System and Standard Functions
18.4
Configuring with STEP 7
18.4.1

Rules for arranging fault-tolerant station components

The are additional rules for a fault-tolerant station, in addition to the rules that generally apply
to the arrangement of modules in the S7-400:
● Insert the CPUs into the same slots.
● Redundantly used external DP master interfaces or communication modules must be
inserted in the same slots in each case.
● Insert an external DP master interface for redundant DP master systems only in the
central controllers and not in the expansion units.
● Redundantly used CPUs must be identical, which means they must have the same article
number, product version and firmware version. It is not the marking on the front side that
is decisive for the product version, but the revision of the "Hardware" component
("Module status" dialog mask) to be read using STEP 7.
● Redundantly used other modules must be identical, which means they must have the
same article number, product version and - if available - firmware version.
302
PROFIBUS DP
Yes
Yes
Yes, internal interface
No, external interface
Yes, internal interface
No, external interface
Yes
No
Applicability
Module status information of all modules
in the specified rack/station
Rack/station status information
Replace this system status list with the
system status list with ID W#16#xy94 in
PROFIBUS DP, as well.
Rack/station status information
Module status information of a submod-
ule using the logical address of this sub-
module
Module status information for the inter-
faces of a module
Module status information of all submod-
ules on an internal interface of a module
using the logical address of the module,
not possible for submodule 0 (= module)
System
.
CPU 410 Process Automation/CPU 410 SMART
System Manual, 05/2017, A5E31622160-AC