10.8.8 Warning Messages and Error Messages

The following is a list of warning messages displayed by LcdUtil17.
No.
When creating or opening a file
・A blank document could not be created.
1
・Unable to create new document
Cause:
Corrective action: Close windows to reduce the number of open windows to 99 or less. Close other applications to increase
2
Unexpected file format
Cause:
Corrective action: Select a file supported by LcdUtil17.
When entering an input
・Enter an integer value between ???? and ????.
3
・Please enter a valid number between ???? and ????.
Cause:
Corrective action: Enter a correct value.
・Enter an integer.
4
・Please enter a valid number. Invalid numbers include: space, decimals, 0, +, -.
Cause:
Corrective action Enter a correct value.
Dot matrix setting window (when [Preview] button is clicked)
5
Invalid ????(???? = position、number of dots、dot size、pitch size、start COM/SEG)
Cause:
Corrective action: Enter a correct value.
Invalid ??? start number or Invalid number of dots (??? = COM、SEG)
6
Cause:
Corrective action: Set the Start ???, dot count, and COM/SEG allocation direction in accordance with the number of
No.
When using [Save as]
7
Some icons/matrixes are out of LCD panel. Remove them? [OK][Cancel]
Cause:
Corrective action: Move the icon or dot matrix so that it does not extend from the LCD panel or click the [OK]
When creating an icon or reading a file
8
The number of the icon is exceeding 4096 pieces.
Cause:
Corrective action: Reduce the total number of icons to less than 4096.
9
The number of the icon is exceeding 4096 pieces. Loaded the icons to 4096 pieces.
Cause:
Corrective action: Reduce the total number of icons to less than 4096.
When creating a matrix or reading a file
10
The number of the matrix is exceeding 10 pieces.
Cause:
Corrective action: Reduce the total number of dot matrices to less than 10.
When saving data or closing a window without saving changes
11
This file was not saved.
Cause:
Corrective action: Data cannot be saved if an icon or dot matrix extends from the LCD panel.
S5U1C17001C Manual
(Rev. 1.0)
Table 10.8.8.1
A new window could not be opened because more than 100 windows are currently open.
A new window could not be opened due to insufficient memory.
available memory.
The file was not in the correct lcd or bmp format. The file was an lcd file with an unsupported driver.
A value outside the allowed range was entered.
A nonnumeric character was entered in the edit box for integer input.
An invalid value is entered in ????.
The number of COM/SEG allowed by the driver has been exceeded, based on settings for Start ???, dot
count, and COM/SEG allocation direction.
COM/SEG allowed by the driver.
An attempt was made to save data while an icon or dot matrix extended from the LCD panel.
button to remove the icon or dot matrix extending from the LCD panel before saving.
The total number of icons exceeded the maximum value of 4096.
The total number of icons exceeded the maximum value of 4096.
The total number of dot matrices exceeded the maximum value of 10.
The icon or dot matrix extending from the LCD panel was not removed.
Seiko Epson Corporation
List of warning messages
10 Other Tools
10-29