Es-Sim17 Error Massages; Restrictions - Epson S5U1C17001C Manual

Cmos 16-bit single chip microcontroller (c compiler package for s1c17 family) (ver. 3.2)
Hide thumbs Also See for S5U1C17001C:
Table of Contents

Advertisement

8.8.7

ES-Sim17 Error Massages

ES-Sim error 01 : Loading the dll file was failed.
ES-Sim error 02 : Opening the CPU construction file was failed.
ES-Sim error 03 : Generating the CPU components was failed.
ES-Sim error 04 : Connecting the CPU components was failed.
ES-Sim error 05 : Opening the "user.ini" was failed.
ES-Sim error 06 : Setting of the "user.ini" is invalid.
Failed to save "path\file"
Failed to open "path\file".
Please confirm the file is fitting with the CPU type, or the file is
existing.
8.8.8

Restrictions

• The ES-Slim17 supports monochrome dot-matrix LCD and monochrome segment LCD panels as external devices.
• The dot size, contrast, and panel color of the LCD window are different from those of the actual LCD panels.
• The ES-Sim17 performs simulation on an instruction cycle basis. Therefore, operation cycles lower than the instruction cycle
cannot be simulated.
• The ES-Sim17 simulates the operation clock based on the instruction cycles. Therefore, the operation timings are not the same as
those of the actual hardware.
• The functions listed below cannot be simulated.
1. Timer clock and oscillation clock external outputs
2. Data transfer using the UART, I
3. Noise and chattering filters
• More than one ES-Sim17 cannot be run on a PC for simulation.
• Setting higher oscillation clock frequency causes degradation of simulation performance.
• The I/O control registers that are not supported by the ES-Sim17 function as general-purpose read/write registers. Also they are
not initialized at a reset.
• Some peripheral circuits, such as the oscillator and SVD circuits, need time until their operations stabilize. In the simulation by
the ES-Sim17, they can operate with stability immediately after they start.
* For the restrictions in the latest version of ES-Sim17 and model dependent restrictions, refer to "simulator_readme.txt".
S5U1C17001C Manual
(Rev. 1.0)
Table 8.7.7.1 Error messages (displayed in the gdb [Console] window)
Message
Table 8.7.7.2 Error messages (displayed in a dialog box)
Message
2
C and SPI
Seiko Epson Corporation
The dll file for ES-Sim17 does not exist in the default location or
cannot be loaded normally.
The CPU configuration file does not exist in the specified location
or cannot be loaded normally.
The ES-Sim17 has failed generation of the CPU module as the
CPU module definition is incorrect or no required dll file exists.
The ES-Sim17 has failed correction to the CPU module generation
as the connect destination in the CPU module definition is
incorrect.
The user setting file does not exist in the specified location or
cannot be opened normally.
The setting value written in the user setting file is incorrect.
The ES-Sim17 has failed saving the captured image to the file.
The LCD file could not be opened.
8 Debugger
Description
Description
8-80

Advertisement

Table of Contents
loading

Table of Contents