Epson S5U1C17001C Manual page 268

Cmos 16-bit single chip microcontroller (c compiler package for s1c17 family) (ver. 3.2)
Hide thumbs Also See for S5U1C17001C:
Table of Contents

Advertisement

Debugger gdb (3)
Debug Commands
Others
set output-rad x
set logging on/off
source file
target type
detach
pwd
cd directory
c17 ttbr
addr
c17 cpu
type
c17 chgclkmd 0/1
c17 pwul
c17 help [command/groupNo.]
addr
c17 model_path
name
c17 model
quit
Change variable display format
ICD Mini/SIM
Log output setting
ICD Mini/SIM
Execute command file
ICD Mini/SIM
Connect target
ICD Mini/SIM
Disconnect target
ICD Mini/SIM
Display current directory
ICD Mini/SIM
Change current directory
ICD Mini/SIM
Set TTBR
SIM
Set CPU type
SIM
DCLK change mode
ICD Mini
Unlock flash security password
ICD Mini
Help
ICD Mini/SIM
Model-specific information file directory
ICD Mini/SIM
setting
MCU model name setting
ICD Mini/SIM
Terminate debugger
ICD Mini/SIM
Status and Error Messages
Status messages
Breakpoint #, function at file:line
Illegal instruction.
Illegal delayed instruction.
Break by key break.
Break by key break. Program received signal
SIGINT, Interrupt.
Error Messages
Address is 24bit over.
Address(0x%lx) is ext or delayed instruction
C17 command error, command is not supported in
present mode.
C17 command error, invalid command.
C17 command error, invalid parameter.
C17 command error, number of parameter.
C17 command error, start address > end address.
Cannot set hard pc break.
Cannot set hard pc break any more.
Cannot set soft pc break.
Cannot set soft pc break any more.
Cannot write file
command result error!
icdmini3 dll open failure.
Development Tools
Made to break at a set breakpoint
Made to break by executing invalid instruction in
simulator mode
Made to break by executing invalid delayed instruction
in simulator mode
Forcibly made to break by [Suspend] button (in
simulator mode)
Forcibly made to break by [Suspend] button (in ICD
Mini mode)
The specified address is out of the 24-bit range. The
maximum S1C17 address size is 24 bits (0xFFFFFF).
The specified address cannot be set due to an ext or
delayed instruction.
The input command cannot be executed in the current
mode (ICD or SIM mode, or neither).
The command is erroneous.
The command is specified with an invalid argument.
The command is specified with an invalid number of
arguments.
The specified start address is greater than the end
address.
Cannot set a hard break at the address specified.
The number of hardware PC breakpoints set exceeds
the limit (one location only).
Cannot set a soft break at the address specified.
The number of software PC breakpoints set exceeds
the limit.
Cannot write to the file.
An error occurred on executing an undefined
command.
Failed to connect to ICD mini Ver3.

Advertisement

Table of Contents
loading

Table of Contents