Installing the STEPDRIVE C Drives
3.4

Error messages and error elimination

3.4
Error messages and error elimination
Name
RDY
green
DIS
yellow
FLT
red
TMP
red
all
3-46
LED
Color
the only
Drive ready
LED that
is lit
the only
Drive ready; motor not powe-
LED that
red
is lit
is lit
There is one of the following
errors:
– Overvoltage or undervoltage
– Short–circuit between the
motor phases
– Short–circuit between motor
phase and ground
is lit
Overtemperature in the drive
No LED is
No operating voltage
lit
Meaning
If the motor does not rotate, it
can have the following causes:
– No pulses are output by the
control system.
– Pulse frequency too high
(motor is "out of step")
– Motor load too large or slug-
gish
Activate ENABLE signal via
CNC
Measure 85 V operating vol-
tage
Check cable connections
Drive defective; replace
Check cable connections
6FC5 597–2AA00–0BP2 (01.02)
Remedy