2.3
Connecting the individual components
Connecting the components
Note
Use only shielded cable and make sure that the shield is connected to the metal or metal pla-
ted connector casing on the control side. For the purpose of isolating the analog setpoint si-
gnal from low–frequency interference, we recommend not to ground the shield on the drive
side.
The preassembled cable offered as accessories provides optimum protection against interfe-
rence.
General procedure:
Proceed as follows to connect the individual components:
1. Connect the cables to the components as shown in Fig. 2-4.
2. Fix the sub–D connector in place using the knurled screws.
2.3.1
Connecting the operator panel
Connector pin assignment on the ENC side
Operator panel interface
Connector designation:
Connector type:
SINUMERIK 802S
6FC5 597–2AA00–0BP2 (01.02)
2.3
Connecting the individual components
X8
OP020
25–pin sub–D plug connector
Installing the Control System
2-21