Table D-1 SPECIFICATIONS: 1222 CONTROLLERS
Nominal input voltage
PWM operating frequency
Maximum encoder frequency
Maximum controller output frequency
Electrical isolation to heatsink
Storage ambient temperature range
Operating ambient temperature range
Internal heatsink operating temp. range
Package environmental rating
Weight
Dimensions, W× L×H
EMC
Safety
UL
Note: Regulatory compliance of the complete vehicle system
with the controller installed is the responsibility of the vehicle OEM.
MODEL
NUMBER
1222-51XX
Notes: All current ratings are rms values per motor phase. Internal algorithms automatically reduce maximum current limit when
heatsink temperature is >85°C or battery voltage is outside the allowed limits. Heatsink temperature is measured internally
near the power MOSFETs.
The 2-minute rating is based on an initial controller heatsink temperature of 25°C and a maximum heatsink temperature
of 85°C. No additional external heatsink is used for the 2-minute rating test.
Operation at or below the continuous rating is required to achieve the lifetime rating.
Ratings are based on the more conservative result of an airflow test and a power capacitor lifetime calculation. For the airflow test,
the controller is mounted on a 6mm thick square steel plate (0.25m 2 ) in a 6km/hr airflow at 25°C temperature. Rated current is when
the controller baseplate temperature reaches 85°C (thermal cutback). The capacitor lifetime calculation assumes internal controller
temperature = 70°C (same as baseplate temperature), modulation index = 60%, and power factor = 0.866.
Curtis 1222 Manual,
os 15
2 9 J A N U A R Y 2 0 1 3
APPENDIX D

SPECIFICATIONS

24–48 V
16 kHz
10 kHz
200 Hz
500 V (minimum)
-40°C to 95°C (-40°F to 203°F)
-40°C to 50°C (-40°F to 122°F)
-40°C to 95°C (-40°F to 203°F)
IP65 per IEC 529
(Note: Compliance requires AMPSEAL 35-pin connector header)
1.3 kg (3.0 lbs)
146 × 164 × 60 mm (5.7" × 6.5" × 2.3")
Designed to the requirements of EN 12895
Designed to the requirements of:
EN 1175-1:1998+A1:2010
ISO 13849-1:2006 (EN 13849-1:2008)
UL recognized component per UL583
NOMINAL
2 MIN
BATTERY VOLTAGE
RATING
(volts)
(amps)
24–48
APPENDIX D: SPECIFICATIONS
CONTINUOUS
RATING
(amps)
70
40
LIFETIME
RATING
(hours)
20,000
D-1