4-7 IT11G0]
AUTOMATIC AIR CONDITIONING SYSTEM
G : TROUBLE CODE (31) - Check air mix door circuit.
CONTENT OF DIAGNOSIS :
31 : Shorted P .B .R . circuit
(P .B .R. : Potentio Balance Resistor)
OK
1
Check P .B.R . circuit.
Not OK
Not OK
2
Check output signals for auto amplifier.
OK
3
Check harness connector between auto amplifier
Not OK
and air mix door .
OK
Replace air mix door motor .
TROUBLE SYMPTOM :
Outlet air temperature does not change. (Compart-
ment temperature cannot be controlled to "set" value .
Check trouble cord 33 .
Repair auto amplifier terminal poor contact . (Replace
auto amplifier .)
Replace and recheck .
Repair harness .