AUTOMATIC AIR CONDITIONING SYSTEM
(T5011 4-7
5. Output Modes of Select Monitor
1 . FUNCTION MODE
Applicable cartridge of select monitor : No . 498348500
MODE
Abbr .
Contents
Unit
Contents of display
F00
-
System identification
-
-
F01
Tset
"Set" temperature
deg °C (°F)
Monitors "Set" temperature
Monitors total signal determined by auto amplifier in
F02
To
Total signal
deg °C (°F)
relation to "set" temperature and signals sent from
in-vehicle sensor, ambient sensor, evaporator sensor,
and sunload sensor .
F03
Troom
Compartment temperature
deg °C (°F)
Monitors compartment temperature determined by
auto amplifier in relation to in-vehicle sensor.
Monitors ambient temperature determined by auto
F04
Tamb
Ambient temperature
deg °C (°F)
amplifier in relation to signal sent from ambient sen-
sor.
Rear-of-evaporator tempera-
Monitors cool air temperature determined by auto
F05
Tevp
ture
deg °C (°F)
amplifier in relation to signal sent from evaporator
sensor .
F06
Qsun
Sunload
kcal
Monitors sunload determined by auto amplifier in
relation to signal sent from sunload sensor .
F07
Tsun
Sunload sensor correction
deg oC (oF)
Monitors total signal correction value in relation to
temperature
sunlight received .
Monitors refrigerant temperature determined by auto
F08
Tref
Refrigerant temperature
deg °C (°F)
amplifier in relation to signal sent from refrigerant
temperature sensor .
Monitors water temperature at lower section of
F09
Tw
Heater core temperature
deg °C (°F)
heater core which is determined by auto amplifier in
relation to signal sent from water temperature sen-
sor.
F10
AMRset
Air mix door target value
oho
Monitors air mix door target opening determined by
total signal (T) .
F11
AMRpot
Actual air mix door opening
%
Monitors actual air mix door opening controlled by
its motor P.B .R . in relation to target opening .
Monitors target outlet value determined from both air
F12
MODEset
Target outlet value
%
mix door target value and temperature at rear of
evaporator .
F13
MODEpot
Actual outlet opening
%
Monitors actual outlet opening .
F14
BLW
Blower level (V)
V
Monitors blower air discharge controlled by auto am-
plifier .
F15
Intak
Intake position
-
Monitors air suction port position .
F16
Isol
Solenoid current output
A
Monitors solenoid current output which is sent from
auto amplifier to control variable compressor .
F17
EGI to A/C
Variable compressor control
%
Monitors "duty" signal which is sent from MPFI unit
signal
to control variable compressor .
FAO
SW
Switch input
-
Monitors switch input .
FBO
DIAG .
Faulty input-output
-
Monitors sensor and door operation .