Subaru SVX 1992 Manual page 1040

Hide thumbs Also See for SVX 1992:
Table of Contents

Advertisement

4-7 IT1000I
AUTOMATIC AIR CONDITIONING SYSTEM
Gauge indication
Refrigerant cycle
Probable cause
Corrective action
High-pressure side is too low and low-
High- and low-pressure sides
Compressor pressure opera-
Replace compressor .
pressure side is too high .
become equal soon after
tion is improper .
compressor operation stops.
l
Damaged inside packings for
1
compressor
LO
HI
No temperature difference
between high and low- pres-
Compressor discharge capac-
ity does not change. (Com-
Replace compressor .
sure sides
pressor stroke is set at maxi-
mum .)
84-715
Fig. 212
Both high- and low-pressure sides are too 0 There is a big temperature
Receiver drier inside is
a Replace receiver drier
low .
difference between receiver
clogged a little .
o Check compressor oil for
drier outlet and inlet. Outlet
contamination .
temperature is extremely
'-'
low .
" Receiver drier inlet and ex-
pansion valve are frosted .
" Temperature of expansion
High-pressure pipe located
0 Check and repair malfunc-
valve inlet is extremely low
between receiver drier and
tioning parts.
LO
HI
as compared with areas
near receiver drier .
expansion valve is clogged .
o Check compressor oil for
contamination .
Expansion valve inlet may
be frosted .
" Temperature difference oc-
84-716
Fig. 213
curs somewhere in high-
pressure side .
Both high and low-pressure sides are too
There is a big temperature
Expansion valve becomes
0 Remove foreign particles by
low .
difference between expansion closed a little compared with
using compressed air .
valve inlet and outlet while
the specification.
o Check compressor oil for
the valve itself is frosted.
l
contamination .
1) Improper expansion valve
adjustment
2) Malfunctioning thermal
valve
3) Outlet and inlet may be
clogged
LO
HI
Area near low-pressure pipe
Low-pressure hose is clogged o Check and repair malfunc-
connection and service valve
or crushed .
tioning parts .
are extremely cold as com-
a Check compressor oil for
pared with area near expan-
contamination .
sion valve outlet and evapora-
tor.
Air flow volume is not
Evaporator is frozen
Replace compressor .
enough or low.
j
Compressor discharge capac-
ity does not change . (Com-
134-716
pressor stroke is set at maxi-
Fig. 214
mum length .)
106