Subaru SVX 1992 Manual page 1041

Hide thumbs Also See for SVX 1992:
Table of Contents

Advertisement

AUTOMATIC AIR CONDITIONING SYSTEM
[T1ooo] 4-7
Gauge indication
Refrigerant cycle
Probable cause
Corrective action
Low-pressure side sometimes becomes
* Air conditioning system
Refrigerant does not dis-
a Drain water from refrigerant
negative .
does not function and does charge cyclically .
cycle or replace refrigerant.
not cyclically cool the com-
1
e Replace receiver drier.
partment air .
Moisture is frozen at expan-
The system constantly func-
lion for a certain period of
sion valve outlet and inlet .
time after compressor is
Water is mixed in refrigeration
stopped and restarted .
cycle .
LO
HI
84-718
Fig. 215
Low-pressure side becomes negative .
Receiver drier or front/rear
High-pressure side is closed
After the system is left at rest,
side of expansion valve's pipe and refrigerant does not flow .
start again in order to confirm
is frosted or dewed .
y
whether or not problem is
Expansion valve or receiver
drier is frosted .
caused by water or foreign
particles .
" If the problem is due to wa-
ter, drain water from refrig-
eration cycle or replace re-
l0
H I
frigerant.
e If it is due to foreign parti-
cles, remove expansion
valve and remove it with
dry and compressed air .
" If either oil the above
method cannot correct the
problem, replace expansion
valve .
Replace receiver drier .
Check compressor oil for
Fig. 216
719
contamination .
107