96
6. Instructions for Factory / Field Installation of High
Speed Verifier Assembly 620008F (Factory) and
620008 (Field)
Installation Procedure - Mechanical
1. Disconnect Power to Printer.
2. Disconnect Stacker Interface Cable.
3. Remove the Rear Cover (save screws).
4. Install the Bracket, Verifier, Mount Base (621303) on the back of the Upright Frame in the (2) 10-32
Pem Nuts in the upper most right side of the Frame. Secure with (2) 10-32 x ¾ Cap Screws.
5. Install the Bracket, Verifier Upright onto the Base Bracket with (2) 8-32 x 3/8 Flat Head Screws.
Tighten securely.
621304 – Bracket, Verifier Upright
990055 – 8-32 x 3/8 FHCS
621303 – Bracket, Verifier,
Mount Base
All manuals and user guides at all-guides.com
User's Manual—SNAP™ 700 Printer
990083 – 10-32 x ¾ SHCS