Maintenance Object Repair Procedures
Table 10-680. TEST #145 Misframe Alarm Inquiry Test — Continued
Error
Code
Result
PASS
0
NO
BOARD
Translation Update Test (#146)
The Translation Update Test sends the circuit-pack-level information specified by
System Administration to the UDS1 Interface circuit pack. Translation includes the
following data administered for a UDS1 Interface circuit pack (see output of
display ds1 UUCSS command): DS1 Link Length between two DS1 endpoints,
Synchronization Source Control, All Zero Suppression, Framing Mode, Signaling
Mode, Time Slot Number of 697-Hz Tone, Time Slot Number of 700-Hz Tone, etc.
In G3V3, if a TN464F or later UDS1 circuit pack is combined with a Avaya 120A1
CSU Module or the 401A T1 Sync Splitter to form an Integrated CSU Module/T1
Sync Splitter, this test will also send the administration for this Integrated CSU to
the circuit pack to assure the board's translations are correct. The administration
of the CSU Module/T1 Sync Splitter is done using the DS1 Circuit Pack
administration form. Translation for the CSU Module/T1 Sync Splitter includes the
following data: Transmit LBO, Receive ALBO, Supply CPE Loopback Jack
Power?, etc.
10-1902
Issue 4 May 2002
Test
No Misframe alarm is detected on the UDS1 Interface circuit
pack.
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted,
an incorrect board is inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the
add ds1 UUCSS command to administer the UDS1
interface if it is not already administered.
2. If the board was already administered correctly, check the
error log to determine whether the board is hyperactive. If
this is the case, the board is shut down. Reseating the board
will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then
issue the busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and
the port.
Description/Recommendation
Continued on next page