ESC O
Disables the skipover perforation (IBM/EPSON).
ASCII Code
Hexadecimal Value
Decimal Value
This sequence sets the number of lines of the skipover perforation to the value 0. Any skip perforation set
by ESC N is cancelled.
ESC Q
Sets the right margin. (EPSON)
ASCII Code
Hexadecimal Value
Decimal Value
Range
This code sets the line length at the current horizontal spacing. It must be sent at the beginning of the line.
The n parameter specifies the number of columns and for each type of horizontal spacing there is a range
of values, as shown in the following table:
Character Width
Double Width
Normal
Any value outside the accepted range is ignored and the previous setting remains in effect. The right
margin must be greater than the left margin. The physical position set for the right margin does not change
if the horizontal spacing is modified.
ESC R
Sets horizontal and vertical tab stops to default values. (IBM)
ASCII Code ESC R
Hexadecimal Value X'1B' X'52'
Decimal Value 27 82
This command sets horizontal tab stops every eight columns starting from column 9 and cancels all
vertical tab stops.
Chapter 1 EPSON/IBM Commands 
ESC O
X'1B' X'4F'
27 79
ESC Q n
X'1B' X'51' n
27 81 n
1 = n = 225
Horizontal Spacing
5 cpi
6 cpi
7.5 cpi
8.5 cpi
10 cpi
10 cpi
12 cpi
15 cpi
17 cpi
20 cpi
 
Range of columns
1 <= n <= 67
1 <= n <= 81
1 <= n <= 101
1 <= n <= 111
1 <= n <= 135
1 <= n <= 135
1 <= n <= 162
1 <= n <= 203
1 <= n <= 232
1 <= n <= 255
26 