X'021101' Invalid Baseline Increment
Explanation: The value of the baseline increment is
not a valid or supported value.
Alternate Exception Action: None.
X'021202' Font Storage is Full
Explanation: There is insufficient pattern storage to
store the font transmitted with the Load Symbol Set
command. There is insufficient storage to load the
data transmitted with the Load Font Equivalence
command.
Alternate Exception Action: None.
X'021401' Invalid Absolute Move Inline Value
Explanation: The Absolute Move Inline parameter
value is not a valid or supported value.
Alternate Exception Action: None.
X'021403'
Explanation: Unsupported Baseline Move
Alternate Exception Action: None.
X'021802' Invalid Font ID
Explanation:
1. The two-byte Font Identifier on a Load Symbol
Set or Load Font Equivalence command is not a
valid or supported value.
2. The one-byte Font Identifier value on the Load
Font Equivalence command is not a valid or
supported value.
3. A font is referenced on a Set Font control, a
Logical Page Description, a Load Symbol Set, a
Write Graphics, or Write Bar Code command, but
the font has not been previously identified by the
Load Font Equivalence command.
4. The font or symbol set referenced in a Logical
Page Description, Write Text, or Write Graphics
command is defined within the current Load Font
Equivalence but is not loaded in the printer.
Alternate Exception Action:
1. None.
2. None.
3. Substitute the active font for the specified local
font and continue processing.
4. Substitute the active coded font for the specified
local font and continue processing.
 
Chapter 6 IPDS Exception Reporting Codes 
 
X'021201' Invalid Intercharacter Adjustment
Explanation:
1. The value of the intercharacter adjustment is
not a valid or supported value.
2. The intercharacter adjustment direction is not
a valid or supported value.
Alternate Exception Action:
1. Ignore the control sequence and continue
presentation
with
according to the hierarchy (the hierarchy is the
last valid value received or if none received then
use the LPD value).
2. Use direction = zero.
Note: In an LPD command, no Alternate
Exception Action occurs.
X'021301' Invalid Absolute Move Baseline
Value
Explanation: The Absolute Move Baseline
parameter value is not a valid or supported
value.
Alternate Exception Action: None.
X'021402' Font to be Deleted Not Found
Explanation: The single byte font specified by
the Deactivate Font command is not in the
machine.
Alternate Exception Action: None.
X'021502' Invalid DF Font
Explanation: The Loaded Font Identifier field is
required in the Deactivate Font command;
however, it is not present or its value is not a
valid or supported value.
Alternate Exception Action: None.
X'021701' Invalid Variable Space Increment
Explanation: The value of the variable space
increment as specified in a text control is not a
valid or supported value.
Alternate Exception Action: None.
222 
PTX‐S828 
the
parameter
values
260071‐001A 

Advertisement

Table of Contents
loading