X'020405' Area Position Reference System is
Not Supported
Explanation: The reference system specified in the
Area Position structured field of the WGC or WBCC
command is not a valid or supported value.
Alternate Exception Action: None.
X'020502' Unsupported Baseline Move
Explanation: Unsupported advancement of the
baseline coordinate toward the I-axis.
Alternate Exception Action: None.
X'020601' Begin Suppression Error
Explanation: Begin Suppression encountered in
the same unit (page, segment or overlay) before
previous suppression in that unit ended.
Alternate Exception Action: None.
X'020705'
Structured
Supported
Explanation: The extents specified in the Output
Control or Data Descriptor structured field of the
WGC or WBCC command are not a valid or
supported value. The window values of the WGC
GDD structured field are not consistent; therefore,
the value of XL is larger than the value of XR or the
value of YB is larger than the value of YT.
Alternate Exception Action: None.
X'020905' Invalid Axis Offsets
Explanation: The axis offsets specified in the
Output Control structured field of the WGC or
WBCC command are not valid or supported values.
Alternate Exception Action: None.
X'020F01' Invalid Text Orientation
Explanation: Baseline or Inline orientation specified
in Set Text Orientation is not a valid or supported
value.
Alternate Exception Action: Use an inline
orientation of 0 degrees and a baseline orientation
of 90 degrees.
 
 
 
 
Chapter 6 IPDS Exception Reporting Codes 
Field
Extents
Not
 
X'020501' Invalid Spanning Sequence
Explanation: A Write Text or Write Graphics
command is required to complete a partial
order, control, or double-byte character code
and another command was received other than
an XOA command.
Alternate Exception Action: None.
X'020505' Structured Field Unit-Base Invalid
Explanation: The unit-base (measurement
units) specified in the Output Control or the Data
Descriptor structured field of the WGC or WBCC
command is not a valid or supported value.
Alternate Exception Action: None.
X'020605' Structured Field Units Invalid
Explanation:
1. The units specified in the Output Control or
the Data Descriptor structured field of the WGC
or WBCC command is not a valid or supported
value.
2. The result of the calculation cannot be
represented in the printer. This may result from
the WGC GDD window limits being very close
together.
3. Coordinate overflow while scaling graphics.
Possible
if
multiplication by a value greater than 1.
Alternate Exception Action: None.
X'020805' Invalid Mapping Option
Explanation: A mapping option specified in the
Output Control structured field of the WGC or
WBCC command is not a valid or supported
value.
Alternate Exception Action: None.
X'020B05' Invalid Structured Field Identifier
Explanation:
identifier in a WGC or WBCC command is
invalid or out of sequence.
Alternate Exception Action: None.
X'021001' Invalid Margin
Explanation: The margin position is not a valid
or supported value.
Alternate Exception Action: None.
221 
scaling
coordinates
A
two-byte
structured
260071‐001A 
PTX‐S828 
require
field