Cleaning The Sprayer Valves - Toro Multi Pro 1750 Operator's Manual

Turf sprayer, serial no. 400000000 and up
Hide thumbs Also See for Multi Pro 1750:
Table of Contents

Advertisement

Cleaning the Sprayer
Valves
To clean the rate-control valve, refer to the
following sections:
1.
Removing the Valve Actuator (page 58)
2.
Removing the Rate-Control-Manifold Valve
(page 59)
3.
Cleaning the Manifold Valve (page 62)
4.
Assembling the Manifold Valve (page 63)
5.
Installing the Rate Control Manifold Valve
(page 64)
6.
Installing the Valve Actuator (page 67)
To clean the agitation valve; refer to the following
sections:
1.
Removing the Valve Actuator (page 58)
2.
Removing the Agitation-Manifold Valve
(page 59)
3.
Cleaning the Manifold Valve (page 62)
4.
Assembling the Manifold Valve (page 63)
5.
Installing the Agitation-Manifold Valve (page
64)
6.
Installing the Valve Actuator (page 67)
To clean the master-section valve, refer to the
following sections:
1.
Removing the Valve Actuator (page 58)
2.
Removing the Master-Section-Manifold
Valve (page 60)
3.
Cleaning the Manifold Valve (page 62)
4.
Assembling the Manifold Valve (page 63)
5.
Installing the Master-Section-Manifold Valve
(page 65)
6.
Installing the Valve Actuator (page 67)
To clean the 3 section valves; refer to the following
sections:
1.
Removing the Valve Actuator (page 58)
2.
Removing the Section-Manifold Valve (page
61)
3.
Cleaning the Manifold Valve (page 62)
4.
Assembling the Manifold Valve (page 63)
5.
Installing the Section Manifold Valve (page
66)
6.
Installing the Valve Actuator (page 67)
Removing the Valve Actuator
1.
Position the sprayer on a level surface, engage
the parking brake, shut off the pump, shut off the
engine, and remove the key.
2.
Remove the 3-pin connector of the valve
actuator from the 3 socket electrical connector
of the sprayer harness.
3.
Remove the retainer that secures the a actuator
to the manifold valve for the rate control,
agitation, master section, or section valve
(Figure
61).
Note:
Squeeze the 2 legs of the retainer
together while pushing it down.
Note:
Retain the actuator and retainer for
installation in
Installing the Valve Actuator (page
67).
Section-Valve Actuator Shown (the agitation-valve actuator
1. Valve actuator (section
valve shown)
2. Retainer
4.
Remove the actuator from the manifold valve.
58
Figure 61
is similar)
3. Stem port
g028237