2.
Assemble the master-section-valve manifold,
gasket, and master-section-bypass valve with a
clamp tightened by hand
3.
Align the flange of the master-section-valve
manifold, a gasket, and the agitation-valve
manifold
(Figure
4.
Assemble the master-section-valve manifold,
gasket, and agitation-valve manifold with a
clamp tightened by hand
5.
Align the flange of the master-section-valve
manifold, a gasket, and the master-section
house
(Figure
77B).
6.
Assemble the master-section-valve manifold
and socket with a clamp tightened by hand
(Figure
77B).
7.
Secure the end-cap fitting to the outlet fitting by
inserting a retainer into the outlet fitting
77B).
8.
Assemble the agitation valve to the valve mount
with the flanged-head bolt and flanged locknut
that you removed in step
Master-Section-Manifold Valve (page 60)
torque the nut and bolt to 1017 to 1243 N∙cm
(90 to 110 in-lb).
Installing the Section Manifold
Valve
1.
Insert the upper end-cap fitting of the manifold
valve into the bypass fitting
Note:
If needed, loosen the mounting hardware
for the bypass fitting to provide clearance.
(Figure
77A).
77B).
(Figure
77B)
3
of
Removing the
(Figure
78A).
1. Flange (reducer coupling)
(Figure
2. Socket (bypass fitting)
3. Bypass fitting
4. Flange (adjacent
manifold—agitation valve)
and
5. End-cap fitting (manifold
valve assembly)
2.
Secure the end-cap fitting to the bypass fitting
by inserting a retainer into the socket of the
bypass fitting
3.
Assemble the outlet fitting onto the lower
end-cap fitting of the manifold valve
78A).
4.
Secure the end-cap fitting to the outlet fitting by
inserting a retainer into the socket of the outlet
fitting
5.
Align a gasket between the flanges of the
reducer coupling and the section valve manifold
(Figure
6.
Assemble the reducer coupling, gasket, and
section valve manifold with a clamp and tighten
by hand
7.
If installing the 2 left most section valves, align
a gasket between the flanges of the 2 adjacent
section valve manifolds
8.
Assemble the 2 adjacent section valve manifolds
and gasket with a clamp and tighten by hand
(Figure
9.
For the left or right boom section valves,
assemble the valves to the valve mount with
the flanged-head bolt and flanged locknut
that you removed in step
Section-Manifold Valve (page 61)
nuts and bolts to 10 to 12 N∙m (90 to 110 in-lb).
66
Figure 78
6. Socket (outlet fitting)
7. Retainer
8. Flange (manifold—section
valve)
9. Gasket
10. Flange clamp
(Figure
78A).
(Figure
78A).
78B).
(Figure
78B).
(Figure
78B).