Error #5 Wrong lamp tem-
perature
Error #6 An unexpected
error occurred
Error #7 No firmware de-
tected
Error #8 Unable to com-
municate
with
control
board
Error #9 Fan error
Error #10 Communication
issue with LCD screen (IC
error)
Error #11 Endstop error
Error #12 Cannot print this
model - it's too tall
Error #14 Temperature
sensor broken or not con-
nected
Error #15 Cannot update
the firmware
52
Temperature of the UV lamp
is too high. The cooling fan
may be faulty.
An unexpected error has
occurred in the application.
There is no firmware installed
in the printer.
No connection with the con-
trol board.
The UV lamp fan has failed.
LCD screen control system
error.
The printer is unable to de-
tect the endstop.
The model exceeds the ac-
ceptable dimension in the
Z-axis.
The
temperature
has failed or may be discon-
nected.
An error has occurred while
updating the firmware.
©2019, Zortrax S.A. All rights reserved. All trade names, logos and trademarks mentioned in the following
document are registered trademarks of Zortrax and are subject to legal protection.
Contact Zortrax Support Center through
the support form:
trax.com/support-form/.
Contact Zortrax Support Center through
the support form:
trax.com/support-form/.
Download the latest firmware update
from
https://support.zortrax.com/down-
loads/. Transfer the update.zar2 file to
a USB flash drive. Plug the USB into the
port at the front of the printer and select
Refresh to start the installation.
Contact Zortrax Support Center through
the support form:
trax.com/support-form/.
Contact Zortrax Support Center through
the support form:
trax.com/support-form/.
Check if the the HDMI and LCD cables
are connected. If the problem reoccurs,
contact Zortrax Support Center through
the support form:
trax.com/support-form/.
Check if the endstop is functioning prop-
erly. Tighten the endstop screw placed
on the guideway fixed block.
If the problem reoccurs, contact Zortrax
Support Center through the support
form:
https://support.zortrax.com/sup-
port-form/.
Prepare the model again in ZSUITE.
sensor
Check if the temperature sensor is prop-
erly connected. If the problem reoccurs,
contact Zortrax Support Center through
the support form:
trax.com/support-form/.
Contact Zortrax Support Center through
the support form:
trax.com/support-form/.