Danfoss FC 101 Quick Manual page 38

Vlt hvac basic drive
Hide thumbs Also See for FC 101:
Table of Contents

Advertisement

Programming
Parameter
1-48 Current at Min Inductance
for d-axis
1-49 Current at Min Inductance
for q-axis
4
4
1-70 PM Start Mode
1-73 Flying Start
3-41 Ramp 1 Ramp Up Time
3-42 Ramp 1 Ramp Down Time
4-12 Motor Speed Low Limit [Hz] 0–400 Hz
4-14 Motor Speed High Limit [Hz] 0–400 Hz
4-19 Max Output Frequency
30-22 Locked Rotor Detection
30-23 Locked Rotor Detection
Time [s]
Table 4.6 Motor Set-up Wizard Settings
Changes Made
The Changes Made function lists all parameters changed
from default settings.
The list shows only parameters which have been
changed in the current edit-setup.
Parameters which have been reset to default
values are not listed.
The message Empty indicates that no parameters
have been changed.
Changing parameter settings
1.
Press the [Menu] key to enter the Quick Menu
until indicator in display is placed above Quick
Menu.
2.
Press [
up, motor set-up or changes made, then press
[OK].
3.
Press [
in the Quick Menu.
4.
Press [OK] to select a parameter.
5.
Press [
setting.
6.
Press [OK] to accept the change.
36
Quick Guide
Range
20–200 %
20–200 %
[0] Rotor Detection
[1] Parking
[0] Disabled
[1] Enabled
0.05–3600.0 s
0.05–3600.0 s
0–400
[0] Off
[1] On
0.05–1 s
] [
] to select the wizard, closed loop set-
] [
] to browse through the parameters
] [
] to change the value of a parameter
Danfoss A/S © 08/2014 All rights reserved.
Default
Usage
100%
Enter the inductance saturation point.
100%
This parameter specifies the saturation
curve of the d- and q-inductance
values. From 20% to 100% of this
parameter, the inductances are
linearly approximated due to
parameters 1-37, 1-38, 1-44, and 1-45.
[0] Rotor Detection
0
Select [1] Enable to enable the
frequency converter to catch a
spinning motor.
Size related
Ramp up time from 0 to rated
1-23 Motor Frequency.
Size related
Ramp down time from rated
1-23 Motor Frequency to 0.
0.0 Hz
Enter the minimum limit for low
speed.
100 Hz
Enter the maximum limit for high
speed.
Size related
Enter the maximum output frequency
value.
[0] Off
0.10 s
7.
Press either [Back] twice to enter Status, or press
[Menu] once to enter the Main Menu.
The Main Menu accesses all parameters.
1.
Press the [Menu] key until indicator in display is
placed above Main Menu.
2.
Press [
] [
] to browse through the parameter
groups.
3.
Press [OK] to select a parameter group.
4.
Press [
] [
] to browse through the parameters
in the specific group.
5.
Press [OK] to select the parameter.
6.
Press [
] [
] to set/change the parameter value.
MG18A602

Advertisement

Table of Contents
loading

Table of Contents