Mitsubishi Electric AE-200A Instruction Book page 22

Air conditioning control system, bacnet function
Hide thumbs Also See for AE-200A:
Table of Contents

Advertisement

*14 It may differ from the actual air direction depending on the type of indoor unit (Ceiling-concealed Ducted, Wall-mounted, Floor-standing).
An example of a Floor standing PFFY-P VKM-E is as follows.
Air direction on the
®
BACnet
Actual air direction
*15 Cannot be used with an indoor unit model.
Differences in supported/not supported objects depending on whether it is an indoor unit, LOSSNAY or the Air To Water model are
indicated on the following page.
*16 Cannot be used with a LOSSNAY which is not interlocked with an indoor unit.
Differences in supported/not supported objects depending on whether it is an indoor unit, LOSSNAY or the Air To Water model are
indicated on the following page.
*17 Cannot be used with an OA Processing Unit which is not interlocked with an indoor unit.
Differences in supported/not supported objects depending on whether it is an indoor unit, LOSSNAY or the Air To Water model are
indicated on the following page.
*18 Cannot be used with an Air To Water model.
Differences in supported/not supported objects depending on whether it is an indoor unit, LOSSNAY or the Air To Water model are
indicated on the following page.
*19 It can only be used if the system controller is AE-200A/AE-50A/EW-50A and the indoor unit is a Setback mode supported model.
*20 Do not use this when "External Input Setting" for AE-200/AE-50/EW-50 is set to "ON/OFF (Level signal)". "External Input Setting" can
be configured on the Initial Setting Tool, Web Browser for Initial Settings, or AE-200/AE-50's LCD. (Refer to the AE-200/AE-50/EW-50
Instruction Book (Initial Settings) for settings methods.)
*21 During Night Purge state, this operates using a specific fan speed and ventilation mode, but these are not reflected in the status display.
As a result, the read status from BACnet
carrying out fan speed and ventilation mode settings during Night Purge state will not change actual operation, and these will only be
reflected in the status display.
*22 "Setback" is available only when the "Old model compatibility mode" is set to "OFF" on the Initial Setting Tool, Web Browser for Initial
Settings, or AE-200/AE-50's LCD.
*23 "Inactive(0),Active(1)" is applied when the object type is BO/BI/BV, and "Text-1(1),Text-2(2),···" is applied when the object type is MO/MI.
®
*24 Use the BACnet
Trial Run Tool to check or set the "Log_Interval" property. (Refer to the AE-200/AE-50/EW-50 Instruction Book (BACnet
Trial Run Tool) for settings methods.)
WT07919X04
Horizontal
Downblow 60%
Upblow 100%
Upblow 80%
®
communications may differ from actual fan speeds and ventilation modes. Additionally,
Setting/Status
Downblow 80%
Downblow 100%
Upblow 60%
Horizontal
22
Swing
Swing
®