7.6 SmartGUARD Fire Alarm Option

Laser cutting and engraving operations using the SmartGUARD device protects the operator, machine,
produced and the work products from potential fire hazards. During the engraving process, flames may
be produced when working with combustible or easily-flammable materials, such as paper or wood. The
SmartGUARD is an optional item that can be set to notify the operator through audio warnings and
automatically shut down the laser firing as a safety precaution.
Note that SmartGUARD fire alarm is an fire detecting and alarm system, not a fire extinguisher.
INSTALLATION:
If you have purchased your system with SmartGUARD, then no installation is required, as your system will
arrive with SmartGUARD pre-installed. For system owners that did not initially purchase this option, but
would now like to add the SmartGUARD, they will need to contact your local authorized GCC distributor to
have this great feature installed.
1. Lift top cover of the C180II using the handle.
123
Remove the rear plate covering
the Y motor and rear panel of
the working area
Insert the SmartGuard
cable through the
opening