Quality Problems
Check focal length setting under Menu function key > Machine Setting > Set Focus Lens to see if it
matches the type of the lens installed.
Check if the focal lens is installed correctly or if focal lens is not fixed properly.
Check if it is caused by the debris or dust builds up in the bearing tracks or x rail.
Check if it is caused from the damaged or dirty focal lens and mirror 4 in the laser carriage which
can not deliver the laser beam effectively.
Non-operational Problems
Laser beam does not generate
1. If the red alignment beam is not revealed, the laser beam is misalignment. Adjust
reflective mirrors for exact focus.
2. If the red alignment beam is revealed, please check the driver power. The laser power
may be too low to be detected. Please increase the percentage setting of the Laser Power
from the software driver or the control panel.
3.
Please check if the laser power connector is loose.
4.
For safety purpose, the laser beam will not be generated when the top or front door is
opened unless you short the connector of the magnetic switches.
NOTE
Unplug the machine before examining the mirrors, lens, motion system or any other part
of the laser system.
Other Problems
Graphic Was Clipped..." Message
The size or location of graphic image may be bigger or beyond legal working area.
Do not place graphic object, especially vectors, right from (3,0) origin position, or 0 at either x or y
rail of working area on application software, Corel Draw for instance, even vector line's width has
been set to the thinnest. Because at thinnest line width, it still goes beyond the boarder and
causes the error. If the message appears randomly but frequently even image object is smaller or
within the legal boarder, check or change DRAM module, a bad contact or faulty DRAM could
cause such error.
Auto Focus Pin is Not Functioning
The focus pin could be stocked by greasy residue that coats on it. Clean the probe with alcohol or
acetone. Check the cable of focus pin, there might be a bad contact or breakage.
When encountering trouble or short circuit problems please press ON/OFF switch to restart the
system.
138