7.5 Troubleshooting for Other Problems Indicated on the Display
7.5.1 Incorrect Value: Check Value
<Cause>
This is displayed when it is detected that the Interface Setup > IP Setting > Default
G/W input value does not match the IP address.
<Probable problem locations>
Operating procedure, system controller
<Remedy>
1.Operation check
Check that the message turns off when the proper value is entered in the Default
G/W.
2.Replace the system controller.
7.5.2 Offline: Load Roll Media
<Cause>
This is displayed when the feed sensor detects no roll media during roll media mode.
<Probable problem locations>
Operating procedure, feed sensor, engine controller and system controller
<Remedy>
1.Operation check
Load the roll media and check if the message changes.
2.Visual check
Remove any foreign objects adhering to the feed sensor.
3.Feed sensor
Check operation using SERVICE MODE>I/O DISPLAY, and replace if anything
does not function normally.
4.Cable connection check
Replace the cable connecting the feed sensor and engine controller if the
connection is not functioning normally.
5.Replace the engine controller.
6.Replace the system controller.