Canon W6200 Service Manual page 133

Hide thumbs Also See for W6200:
Table of Contents

Advertisement

Part 4: Technical Reference
c) Signal contact points
The signal contact points on the printhead are connected to the signal contact points
on the head relay PCB so that print signals and other information are sent from the
carriage relay PCB to the nozzles.
Table 4-2 SIGNALS AND PIN NUMBERS OF SIGNAL CONTACT POINTS (1/2)
Pin number
1,2,3
4
5
6
7,8
9
10
11
12,13,14,15
16
17
18
19
20
21
22
23
24,25
26
27
28
29
30
Figure 4-15 Signal Contact Points
Signal
IN/OUT
HGND
-
E_DTLM1
IN
E_DTLC1
IN
O_DTLM2
IN
GND
-
E_DTC1
IN
E_DTC2
IN
O_DTC2
IN
HGND
-
SHE_LC
IN
O_DTLC1
IN
SHE_BK
IN
SHE_LM
IN
HE_LM
IN
GND
-
E_DTM2
IN
LTH
IN
HGND
-
VHFBG
-
DIALC()
OUT
DIAK()
OUT
DIAK()
OUT
O_DTBKI
IN
1
2
3
4
5
6
7
8
14 15 16 17 18 19 20 21 22 23 24 25 26
27 28 29 30 31 32 33 34 35 36 37 38 39
40
41
42
43
44
45
46
47
53 54 55 56 57 58 59 60 61 62 63 64 65
66
67
68
69
70
71
72
73
Function
GND
Nozzle data signal (M nozzle array/even nozzle)
Nozzle data signal (C nozzle array/even nozzle)
Nozzle data signal (M nozzle array/odd nozzle)
GND
Nozzle data signal (C nozzle array/even nozzle)
Nozzle data signal (C nozzle array/even nozzle)
Nozzle data signal (C nozzle array/odd nozzle)
GND
Sub heat enable signal (PC nozzle array)
Nozzle data signal (PC nozzle array/odd nozzle)
Sub heat enable signal (Bk nozzle array)
Sub heat enable signal (PM nozzle array)
Heat enable signal (PM nozzle array)
GND
Nozzle data signal (M nozzle array/even nozzle)
Data latch signal
GND
NC
DI sensor signal (PC nozzle array)
DI sensor signal (Bk nozzle array)
DI sensor signal (Bk nozzle array)
Nozzle data signal (Bk nozzle array/odd nozzle)
4-24
9 10 11 12 13
48
49
50
51
52
74
75
76
77
78
W6200