Table 6-8 Udt 260 "Mds Status (Mode 1, Rf300); Table 6-9 Udt 270: "Mds Status (Mode 2, Rf300) - Siemens SIMATIC FC 45 Function Manual

Sensors
Table of Contents

Advertisement

Examples/applications
6.7 UDTs of FB 45 / FC 45
UDT 260: Result of MDS status (mode 1, RF300)
Table 6-8
UDT 260 "MDS status (mode 1, RF300)"
Address
Name
0.0
+0.0
status_info
+1.0
UID
+9.0
MDS_type
+10.0
Lock_state
+11.0
res.
to
+16.0
=18.0
UDT 270: Result of MDS status (mode 2, RF300)
Table 6-9
UDT 270: "MDS status (mode 2, RF300)"
Address
Name
0.0
+0.0
status_info
+1.0
UID
+9.0
LFD
+10.0
FZP
+11.0
FZP
+12.0
ANWZ
+13.0
res.
to
+16.0
=18.0
6-18
Type
Comment
STRUCT
BYTE
MDS status mode
ARRAY[1...8]
Number of MDS (unique identifier)
BYTE
BYTE
MDS type
01 = Tag without FRAM
02 = Tag with FRAM 8KB
03 = Tag with FRAM 32KB
04 = Tag with FRAM 64KB
BYTE
EEPROM write protection status
Reserved
END_STRUCT
Type
Comment
STRUCT
BYTE
MDS status mode
ARRAY[1...8]
Number of MDS (unique identifier)
BYTE
BYTE
Relationship between power flow density
limit and actual measured value
BYTE
Error counter, passive (errors during idle
time)
BYTE
Error counter, active (errors during
communication)
BYTE
Presence counter
BYTE
Reserved
END_STRUCT
Function manual, Release 03/2006 , J31069-D0167-U001-A2-7618
FC 45

Advertisement

Table of Contents
loading

Table of Contents