Table 6-5 Udt 120 "Moby Write/Read Device-Stat Diag 1" - Siemens SIMATIC FC 45 Function Manual

Sensors
Table of Contents

Advertisement

UDT 120: Result of write/read device diagnosis I
Table 6-5
UDT 120 "MOBY write/read device-Stat Diag 1"
Address
Name
0.0
+0.0
status_info
+1.0
number_functions
+2.0
function_01_01
+3.0
function_01_02
+4.0
function_01_03
.
.
.
.
.
.
=234.0
*) An area of seven bytes each is reserved for 33 commands.
UDT 130: Result of write/read device diagnosis II
Table 6-6
UDT 130 "MOBY write/read device-Stat Diag 2"
Address
Name
0.0
+0.0
status_info
+1.0
number_errors
+2.0
error_number
*1.0
=238.0
UDT 140: Result of write/read device diagnosis III
Table 6-7
UDT 140 "MOBY write/read device-Stat Diag 3"
Address
Name
0.0
+0.0
status_info
+1.0
number_MDS
+2.0
UID
*4.0
=98.0
FC 45
Function manual, Release 03/2006 , J31069-D0167-U001-A2-7618
Type
STRUCT
BYTE
BYTE
BYTE
BYTE
BYTE
END_STRUCT
Type
STRUCT
BYTE
BYTE
ARRAY [1...235]
BYTE
END_STRUCT
Type
STRUCT
BYTE
BYTE
ARRAY [1...24]
DWORD
END_STRUCT
Comment
Write/read device status mode
Range: 1...33
*
*
*
Comment
Write/read device status mode
Range: 1...235
Error appeared on write/read device
Comment
Write/read device status mode
Range: 1...24
Identified UID (MDS number)
Examples/applications