Siemens SIMATIC FC 45 Function Manual page 68

Sensors
Table of Contents

Advertisement

Examples/applications
6.2 Processing of data memories/transponders
RF300: Address mapping on the transponder
R/W EEPROM memory and OTP memory is only available once on the transponder.
The following table shows the mapping of addresses on the transponder.
Data can be read via the R/W address or the OTP address.
Notice
Write access to addresses starting at FF80 to FF93 activates the write protection (OTP
function) on the EEPROM user memory. This operation is not reversible. Switching on write
protection must always take place in ascending order without gaps, starting at address FF80.
See also
MOBY commands (Page 3-11)
6-6
R/W EEPROM
Address
FF00
FF01
FF02
FF03
FF04
FF05
FF06
FF07
FF08
FF09
FF0A
FF0B
FF0C
FF0D
FF0E
FF0F
FF10
FF11
FF12
FF13
Length
1 .. 20
1 .. 19
1 .. 18
1 .. 17
1 .. 16
1 .. 15
1 .. 14
1 .. 13
1 .. 12
1 .. 11
1 .. 10
1 .. 9
1 .. 8
1 .. 7
1 .. 6
1 .. 5
1 .. 4
1 .. 3
1 .. 2
1
Function manual, Release 03/2006 , J31069-D0167-U001-A2-7618
Write OTP once
Address
FF80
4,8,12,16,20
FF84
FF88
FF8C
FF90
Length
4,8,12,16
4,8,12
4,8
4