Configuring the instructions
4.5 Programming add-on instructions
4.5.4

Status instructions

4.5.4.1

Reader_Status

The "Reader_Status" instruction reads status information from the reader or communications
module ("CM configuration_1" module) For the various reader families, there are different
status modes that you can select using the "ATTRIBUTE" parameter.
Figure 4-20
Table 4- 24
Parameter
ATTRIBUTE
IDENT_DATA
44
Instruction "Reader_Status"
Explanation for the instruction "Reader_status"
Data type
SINT
SINT[10]
Default values
Description
0x81
Identifier of the status modes / possi-
ble entries:
RF200: 0x81
RF300: 0x81, 0x86
RF620R, RF630R: 0x87, 0x88,
0xA0, 0xA1
RF68xR: 0x89
0
Event values depending on attributes
Note:
When necessary, an array of any size
can be transferred to this parameter.
Note that the array must be ≥ 10 bytes
long (e.g. "SINT[12400]").
Ident profile, Add-on instruction for Rockwell systems