Siemens SIMATIC FC 45 Function Manual page 22

Sensors
Table of Contents

Advertisement

Parameterizing
3.1 Parameter data block
Variable
The following should be carefully noted:
MOBY_mode may only be changed after an ASM is turned on.
scanning_time
MOBY I/V:
Scanning_time is the scanning time for the MDS 507 of MOBY I and MOBY V. A value of 00 can be
used here for all other types of MDS. The scan time setting (ABTA) is shown below (see also
configuration manual of write/read device 44/MDS 507).
Example: A scanning time of 1 second results in ABTA = 81 hex for the parameter.
3-4
0
Default
1
MOBY I or MOBY E
(without MDS 507)
4
MOBY I with MDS 507
5
MOBY U/D or RF300 - without multitag handling
6
Res. for MOBY U - with multitag handling (FB 55)
7
Res. for MOBY D or RF300 - with multitag handling
(FB 55)
8
MOBY I dialog
9
MOBY V
A
MOBY F with MDS F1xx
B
MOBY F with MDS F4xx
C
MOBY F (res. for MDS F2xx)
Description
-; Reserved for setting the operating
mode with switch or GSD
parameterization. Various interfaces
without switches interpret MOBY mode
= 0 as MOBY I mode.
all
452; 454
475; 473; 452
454; 452
452
475; 473: 452; 854; 850
475; 473: 452; 854; 850
Function manual, Release 03/2006 , J31069-D0167-U001-A2-7618
FC 45

Advertisement

Table of Contents
loading

Table of Contents