Input parameters for ASM 473
The assignment is made in UDT 10 (see Section "Parameter data block").
Table A-3
Input parameters for ASM 473
Address
Name
+0.0
ASM_address
+2.0
ASM_channel
+8.0
MDS_control
+9.0
ECC_mode
+9.1
RESET_long
+10.0
MOBY_mode
+11.0
scanning_time
+12.0
option_1
+13.0
distance_limiting
+14.0
multitag
+15.0
field_ON_control
+16.0
field_ON_time
1) valid only for 6GT2 002-0HA10
Table of commands for ASM 473
The assignment is made in UDT 20 using the "Command" variable (see Section "Command
parameter settings").
Table A-4
1) These commands are only available for 6GT2 002-0HA10.
2) Please read Section "Command parameters".
3) Chained commands are not supported by all write/read devices. Bitte beachten Sie entsprechende
Please adhere to the information
in the MOBY manuals for configuration, mounting and service.
FC 45
Function manual, Release 03/2006 , J31069-D0167-U001-A2-7618
Permissible values
256, 260, 264, 268, ...
1
B#16#0, 1
TRUE, FALSE
TRUE, FALSE
B#16#1, 5, A, B
B#16#00 ... FF
B#16#00, 02, 04, ...
B#16#05, 0A, 0F, 14,
19, 1E, 23
B#16#1
B#16#0, 1, 2
B#16#00 ... FF
Commands for ASM 473
Command code
normal
Chained
3
01
41
02
42
03
43
04
44
08
48
0A
4A
0B
4B
Automatic or manual address assignment
Each ASM 473 occupies four bytes of
I/O in the peripheral area of the
controller.
1 channel per ASM
Enable/disable presence check
TRUE is only permitted when MOBY_mode
is parameterized with 1.
TRUE,
if MOBY_mode = 5 (MOBY U or RF300)
MOBY I/E/F/U
A value other than 00 is only
recommended when MOBY_mode was
parameterized appropriately (see
Section "INPUT parameters").
See Section "INPUT parameters"
MOBY U
(see Section "INPUT parameters")
MOBY U
MOBY U
(see Section "INPUT parameters")
MOBY U
(see Section "INPUT parameters")
Description
Write to MDS
Read MDS; read fixed code
Initialize MDS
Write/read device status
1
END
1
Turn antenna on/off
MDS status
1
Brief description of ASM hardware
Comment
1
1
/D
1
1
/D
1
1
1
/D
or RF300
1
1
/D
1
1
/D
available in
the MOBY system
U/D
2
F/U/D or RF300
U or RF300
A.2 ASM 473
all
all
all
or RF300
2
U