Siemens SIMATIC FC 45 Function Manual page 89

Sensors
Table of Contents

Advertisement

Input parameters for ASM 473
The assignment is made in UDT 10 (see Section "Parameter data block").
Table A-3
Input parameters for ASM 473
Address
Name
+0.0
ASM_address
+2.0
ASM_channel
+8.0
MDS_control
+9.0
ECC_mode
+9.1
RESET_long
+10.0
MOBY_mode
+11.0
scanning_time
+12.0
option_1
+13.0
distance_limiting
+14.0
multitag
+15.0
field_ON_control
+16.0
field_ON_time
1) valid only for 6GT2 002-0HA10
Table of commands for ASM 473
The assignment is made in UDT 20 using the "Command" variable (see Section "Command
parameter settings").
Table A-4
1) These commands are only available for 6GT2 002-0HA10.
2) Please read Section "Command parameters".
3) Chained commands are not supported by all write/read devices. Bitte beachten Sie entsprechende
Please adhere to the information
in the MOBY manuals for configuration, mounting and service.
FC 45
Function manual, Release 03/2006 , J31069-D0167-U001-A2-7618
Permissible values
256, 260, 264, 268, ...
1
B#16#0, 1
TRUE, FALSE
TRUE, FALSE
B#16#1, 5, A, B
B#16#00 ... FF
B#16#00, 02, 04, ...
B#16#05, 0A, 0F, 14,
19, 1E, 23
B#16#1
B#16#0, 1, 2
B#16#00 ... FF
Commands for ASM 473
Command code
normal
Chained
3
01
41
02
42
03
43
04
44
08
48
0A
4A
0B
4B
Automatic or manual address assignment
Each ASM 473 occupies four bytes of
I/O in the peripheral area of the
controller.
1 channel per ASM
Enable/disable presence check
TRUE is only permitted when MOBY_mode
is parameterized with 1.
TRUE,
if MOBY_mode = 5 (MOBY U or RF300)
MOBY I/E/F/U
A value other than 00 is only
recommended when MOBY_mode was
parameterized appropriately (see
Section "INPUT parameters").
See Section "INPUT parameters"
MOBY U
(see Section "INPUT parameters")
MOBY U
MOBY U
(see Section "INPUT parameters")
MOBY U
(see Section "INPUT parameters")
Description
Write to MDS
Read MDS; read fixed code
Initialize MDS
Write/read device status
1
END
1
Turn antenna on/off
MDS status
1
Brief description of ASM hardware
Comment
1
1
/D
1
1
/D
1
1
1
/D
or RF300
1
1
/D
1
1
/D
available in
the MOBY system
U/D
2
F/U/D or RF300
U or RF300
A.2 ASM 473
all
all
all
or RF300
2
U
A-7