A.7 ASM 850
Input parameters for ASM 850
The assignment is made in UDT 10 (see Section "Parameter data block").
Table A-18
Address
+0.0
+2.0
+8.0
+9.0
+9.1
+10.0
+11.0
+12.0
+13.0
+14.0
+15.0
+16.0
Table of commands for ASM 850
The assignment is made in UDT 20 using the "Command" variable (see Section "Command
parameter settings").
Table A–18 Commands of the ASM 850
The command table is valid for the FB 45. No commands are transferred to the ASM when
fixed-code MDSs are processed with the process image.
Switch settings, interfaces and indicators of the ASM 850
See Section "Switch settings, interfaces and indicators of the ASM 454" in Chapter "ASM
454"
A-30
Input parameters for ASM 850
Name
ASM_address
ASM_channel
MDS_control
ECC_mode
RESET_long
MOBY_mode
scanning_time
option_1
distance_limiting
multitag
field_ON_control
field_ON_time
Command code
normal
Chained
01
41
02
42
03
43
0A
4A
Permissible
values
256, 264, 272,
Each ASM 850 occupies 8 byte
280, ...
of I/O in the I/O area of the
control unit
1
1 channel
B#16#0, 1
0= no presence check
1= presence check
FALSE
No ECC driver
FALSE
(no MOBY U)
B#16#A, B
Only MOBY F parameterization
B#16#00
No parameterization of the
scanning time
B#16#00, 01, 04,
(See Section "INPUT
08
parameters")
B#16#0
Not relevant (no MOBY U)
B#16#1
B#16#0
B#16#0
Write to MDS
Read MDS; read fixed code
Initialize MDS
Antenna on/off