14 Command Channel (DB 41)

14.4.9 Useful data of the function "temperature compensation"

14.4.9 Useful data of the function "temperature compensation"
Function number 9
Temperature compensation is required if the thermal expansion of certain machine parts
causes an offset between the measuring system and the tool or workpiece.
There are two types of compensation, which can be used individually or together.
In position-dependent temperature compensation, the compensation value is directly
proportional to the distance between the actual value and a reference point at which no
compensation is required. The resulting error curve is defined by the reference point and its
gradient (coefficient).
In absolute temperature compensation, the deviation of the measuring system is compensated
independently of the position.
Useful data
DB/DX
Bit 15
DW x
DW x+1
DW x+2
DW x+3
DW x+4
DW x+5
DW x+6
DW x+7
Overview of the useful data for the "temperature compensation" function"
_______
d)
with GA2, software version 1 and higher
14–22
DL
Length of the useful data in words: 7
Axis number
High
Absolute temperature compensation
Low
High
Coefficient
Low
High
Reference point
Low
© Siemens AG 1991 All Rights Reserved
DR
Bit 0
U
A
d)
6ZB5 410-0HE02
SINUMERIK 880 (PJ)
01.93