5 Description of Basic Signals (FY 0 ... FY 24)
5.6 Diagnostics (DB 1)
Assignment of the status registers:
Bit
0
DEZNAU
1
Wire-break
2
Transmission error
3
Overtemperature
4
OUTDS
5
Change of configuration input
6
Change of configuration output
7
Module started
Detailed error coding in diagnostics DB (DB 1)
In order to display the PLC detailed error coding on the NC screen ERRCODE error numbers
and the supplementary error data in the diagnostics DB (DB 1) are stored in the data words
c)
160 to 163
or DW 160 to 164
contents of ACCU 1 and ACCU 2 (low words) are stored in data words 166 and 167
DW 160
DW 161
Supplementary error data
DW 162
Supplementary error data
DW 163
Supplementary error data
DW 164
Supplementary error data
DW 165
Spare
DW 166
ACCU 1, Low word
DW 167
ACCU 2, Low word
_______
c)
up to and including software version 6
d)
with GA2, software version 1 and higher
5–16
Meaning
d)
(equivalent to PG function OUTPUT ADDR:PLC, F0000). The
Diagnostics DB
DB 1
Error number
d)
d)
© Siemens AG 1991 All Rights Reserved
Same as address with
OUTPUT ADDR:PLC
F0000
1st word
F0001
2nd word
F0002
3rd word
F0003
d)
4th word
F0004
6ZB5 410-0HE02
SINUMERIK 880 (PJ)
01.93