3 Signal Overview
3.17 Decoding lists for M signals (DB 80 ... DB 95)
3.17
Decoding lists for M signals (DB 80 ... DB 95)
Decoding lists for M signals (Section 18)
DW No.
High byte (DL)
PLC
DW
m+0
DW
m+1
DW
Bit address, DW No.
m+2
Notes:
•
Address m is derived from the following number of the M function definition:
M function
1
2
3
.
.
.
64
•
The table must be completed consecutively starting with the first entry. No gaps are
allowed between entries. If fewer than 64 M functions are defined, the remaining entries
must be pre-assigned with 0. All unavailable entries are at the end of the table.
•
The decoding lists are channel-specific; decoding list DB 80 is intended for NC channel 1,
so that DB 95 accordingly belongs to NC channel 16.
•
M decoding according to list is activated as a channel-specific function by means of MDs.
3–76
Extended address
M address
m
0
3
6
.
.
.
189